Slit lamp details

Meibomian gland examination
The high-resolution camera and specialized infrared illumination enable detailed imaging of the meibomian glands, assisting in the diagnosis and documentation of meibomian gland dysfunction (MGD) and dry eye disease.

Built-in yellow filter
The built-in yellow filter combined with the cobalt-blue filter significantly improves the contrast of sodium fluorescein staining images, increasing the detection rate of early corneal epithelial defects.

High optical resolution
The patient management system enables clinicians to build and edit patient record,search information by inputting keywords.Clinicians can easily record symptoms and manage the data all the time. The software supports DICOM which makes the images captured by Firefly be easily integrated into hospital’s medical system.

Advanced imaging performance
Equipped with a 1/2.5″ sensor, the system captures crystal-clear images at resolutions up to 4056 × 3040 pixels and 2592 × 1952 pixels, supporting a smooth 25 fps frame rate for real-time observation.
Software details

Convenient patient management
The patient management system enables clinicians to build and edit patient record,search information by inputting keywords.Clinicians can easily record symptoms and manage the data all the time. The software supports DICOM which makes the images captured by Firefly be easily integrated into hospital’s medical system.

Functional image analysis
Clinicians can measure the pathology area with our powerful software tools and change the contrast and brightness of the images. Clinicians can also compare several images at one time to analyze the symptoms and pathology.

Orthokeratology lens fitting assistance
The optometrists can capture and record high resolution fluorescein images of lens fitting and real-time video without a recording time limit. By comparing the different lens fitting effects, the optometrist can show and educate patients which lens is most suitable for them.

Customized auto exposure value setting
Clinicians can customize auto exposure values according to the image demand and save as templates for future capturing purpose. Also, the printing report can be customized according to clinician’s needs.

The most effective tools for dry eye

Meibomian gland observation
Built-in infrared light source allows the doctor to accurately judge the absence of the meibomian glands.

Tear film breakup time
High-performance digital module, doctors can get the tear film Breakup time and judge the stability of it by high-resolution video recording.

Red eyes analysis and keratopathy exposure
With a built-in yellow filter, doctors can accurately analyze eye surface damage and inflammation images.

Tear meniscus height
Doctors can obtain tear meniscus height by using measuring function in the Mediview softwarae, and effectively evaluate tear meniscus height.